DIN Rail Timer Relay, TMS2, Power-on Delay
$29.32
$49.26
Introduction: Our TMS2 product is a power-on delay type DIN rail timer relay. An on delay timer is a switch used to delay the start of a load, there is a set time interval between the power on time and the load on time. This DIN rail timer relay has delay times of 1 second, 5 seconds, 15 seconds, 30 seconds, 60 seconds, 10 minutes, 30 minutes and 1 hour and is adjustable 0-100%. For example, you set the first dial is 5 seconds, second dial 50%, the delay time is 5*50%=2.5 seconds. Compared with our TMM1 programmable multi-function timer relay, it is more economical and simpler to operate due to its single function. This product is very space-saving, with a width of only 18mm, and many pieces can be fixed on a 35mm DIN rail. The contact type can be SPDT(1 NO 1 NC, 5A), SPDT(1 NO 1 NC, 16A), DPDT(2 NO 2 NC, 5A), SPST(1 NO, 16A). Please contact us for recommendations for your applications. Want to get the latest pricing or technical support from us for this TMS2 DIN Rail Timer Relay? Fill out the form below to contact us today! TMS2 DIN Rail Timer Relay Timing Chart: Specifications: Model TMS2 Working voltage 24-240VAC/DC Time delay range 0-1 hour(selection through dial) Setting accuracy ±10%±100ms Repeatable accuracy ±0.2%±50ms Power-up repetition interval >=0.2s </td></tr><tr style="height:px" ><td data-cell-id="A7" data-x="0" data-y="7" data-db-index="7" class="htCenter htMiddle bg-c7c7c7" data-cell-type="text" data-original-value="Rated insulation voltage" data-order="Rated insulation voltage" >Rated insulation voltage </td><td data-cell-id="B7" data-x="1" data-y="7" data-db-index="7" class="htCenter htMiddle bg-c7c7c7" data-cell-type="text" data-original-value="AC415V" data-order="AC415V" >AC415V </td></tr><tr style="height:px" ><td data-cell-id="A8" data-x="0" data-y="8" data-db-index="8" class="htCenter htMiddle" data-cell-type="text" data-original-value="Utilisation category" data-order="Utilisation category" >Utilisation category </td><td data-cell-id="B8" data-x="1" data-y="8" data-db-index="8" class="htCenter htMiddle" data-cell-type="text" data-original-value="AC-15" data-order="AC-15" >AC-15 </td></tr><tr style="height:px" ><td data-cell-id="A9" data-x="0" data-y="9" data-db-index="9" class="htCenter htMiddle bg-c7c7c7" data-cell-type="text" data-original-value="Contact capacity" data-order="Contact capacity" >Contact capacity </td><td data-cell-id="B9" data-x="1" data-y="9" data-db-index="9" class="htCenter htMiddle bg-c7c7c7" data-cell-type="text" data-original-value="SPDT(1 NO 1 NC, 5A), SPDT(1 NO 1 NC, 16A), DPDT(2 NO 2 NC, 5A), SPST(1 NO, 16A)" data-order="SPDT(1 NO 1 NC, 5A), SPDT(1 NO 1 NC, 16A), DPDT(2 NO 2 NC, 5A), SPST(1 NO, 16A)" >SPDT(1 NO 1 NC, 5A), SPDT(1 NO 1 NC, 16A), DPDT(2 NO 2 NC, 5A), SPST(1 NO, 16A) </td></tr><tr style="height:px" ><td data-cell-id="A10" data-x="0" data-y="10" data-db-index="10" class="htCenter htMiddle" data-cell-type="text" data-original-value="Electrical durability" data-order="Electrical durability" >Electrical durability </td><td data-cell-id="B10" data-x="1" data-y="10" data-db-index="10" class="htCenter htMiddle" data-cell-type="text" data-original-value="100000 cycles" data-order="100000 cycles" >100000 cycles </td></tr><tr style="height:px" ><td data-cell-id="A11" data-x="0" data-y="11" data-db-index="11" class="htCenter htMiddle bg-c7c7c7" data-cell-type="text" data-original-value="Mechanical durability" data-order="Mechanical durability" >Mechanical durability </td><td data-cell-id="B11" data-x="1" data-y="11" data-db-index="11" class="htCenter htMiddle bg-c7c7c7" data-cell-type="text" data-original-value="1000000 cycles" data-order="1000000 cycles" >1000000 cycles </td></tr><tr style="height:px" ><td data-cell-id="A12" data-x="0" data-y="12" data-db-index="12" class="htCenter htMiddle" data-cell-type="text" data-original-value="Pollution degree" data-order="Pollution degree" >Pollution degree </td><td data-cell-id="B12" data-x="1" data-y="12" data-db-index="12" class="htCenter htMiddle" data-cell-type="text" data-cell-format-type="number" data-original-value="3" data-order="3" >3 </td></tr><tr style="height:px" ><td data-cell-id="A13" data-x="0" data-y="13" data-db-index="13" class="htCenter htMiddle bg-c7c7c7" data-cell-type="text" data-original-value="Degrees of protection" data-order="Degrees of protection" >Degrees of protection </td><td data-cell-id="B13" data-x="1" data-y="13" data-db-index="13" class="htCenter htMiddle bg-c7c7c7" data-cell-type="text" data-original-value="IP20" data-order="IP20" >IP20 </td></tr><tr style="height:px" ><td data-cell-id="A14" data-x="0" data-y="14" data-db-index="14" class="htCenter htMiddle" data-cell-type="text" data-original-value="Uimp" data-order="Uimp" >Uimp </td><td data-cell-id="B14" data-x="1" data-y="14" data-db-index="14" class="htCenter htMiddle" data-cell-type="text" data-original-value="4kV" data-order="4kV" >4kV </td></tr><tr style="height:px" ><td data-cell-id="A15" data-x="0" data-y="15" data-db-index="15" class="htCenter htMiddle bg-c7c7c7" data-cell-type="text" data-original-value="SCPD" data-order="SCPD" >SCPD </td><td data-cell-id="B15" data-x="1" data-y="15" data-db-index="15" class="htCenter htMiddle bg-c7c7c7" data-cell-type="text" data-original-value="NT00-6A" data-order="NT00-6A" >NT00-6A </td></tr><tr style="height:px" ><td data-cell-id="A16" data-x="0" data-y="16" data-db-index="16" class="htCenter htMiddle" data-cell-type="text" data-original-value="Power consumption" data-order="Power consumption" >Power consumption </td><td data-cell-id="B16" data-x="1" data-y="16" data-db-index="16" class="htCenter htMiddle" data-cell-type="text" data-original-value="AC:<=1W DC:<=0.5W" data-order="AC:<=1W DC:<=0.5W" >AC:<=1W DC:=0.2s Rated insulation voltage AC415V Utilisation category AC-15 Contact capacity SPDT(1 NO 1 NC, 5A), SPDT(1 NO 1 NC, 16A), DPDT(2 NO 2 NC, 5A), SPST(1 NO, 16A) Electrical durability 100000 cycles Mechanical durability 1000000 cycles Pollution degree 3 Degrees of protection IP20 Uimp 4kV SCPD NT00-6A Power consumption AC:Storage temperature -25-55℃,Up to 70℃ in a short time (24h) Permissible relative humidity Operation temperature -10-50℃ Height above sea level Installation DIN rail mounting WordPress Data Table Plugin
Time Delay Relay